Series TFXP Transit Time Ultrasonic Flow Meter Operations & Maintenance Manual

Página 2

Rev. 5/09 -1.8- TFXP PART 1 - INTRODUCTION The TFXP employs modular construction and provides electr

Página 3 - BEFORE OPERATING THE TFXP

Rev. 5/09 -A.4- TFXP UNIT list. Select the appropriate RATE INTERVAL from the list (seconds, minute

Página 4 - TABLE OF CONTENTS

Rev. 5/09 -A.5- TFXP Accuracy The accuracy of BTU measurements relies on two separate measurements

Página 5

Rev. 5/09 -A.6- TFXP NOTES HEAT FLOW ADDENDUM

Página 7

BSC MENU DATALOG LINER TYPE * EBONITE MORTAR HDPE LDPE POLYPRO POLYSTY RUBBER TAR EPXY TEFLON OTHER RATE INT

Página 8

CH PSWD? 0-9999 DSP MENU Keypad Operations 1. The (soft)MENU key is pressed from RUN mode to enter PROGRAM mode. The (soft)EXIT key is pressed

Página 9

TFX Error Codes Revised 2-22-2002 Code Number Description Correction Warnings 0001 Serial number not present Hardware serial number has become i

Página 10 - TFXP -    A -  

K-Factors Explained The K-factor (with regards to flow) is the number of pulses that must be accumulated to equal a particular volume of fluid. You

Página 11 - PART 1 - SPECIFICATIONS

Example 2 Known values are: Full Scale Flow Rate = 85 GPM Full Scale Output Frequency = 650 Hz 650 Hz x 60 sec = 39,000 pulses per min 3

Página 12 - Installation

4) What is the flow rate in GPM at 4.3 ft/sec. 0.384 gallons x 4.3 FPS x 60 sec (1min) = 99.1 GPM Now that the volumetric flow rate is know all t

Página 13 - Connections

Rev. 5/09 -1.9- TFXP PART 1 - SPECIFICATIONS TRANSMITTER Power Requirements Internal 12 V lead-aci

Página 14 - Sources

Fluid PropertiesOriginal Date: 7/30/1999Revision: ARevision Date: 9/10/2003File: I:/dynasonics/dyna_code/tables/fluid_ss.xlsFluid Specific Gravity

Página 15 - ISO-MODs

Oil, Castor 0.97 1477 4845.8 3.6 0.670 0.649Oil, Diesel 0.80 1250 4101Oil (Lubricating X200) 1530 5019.9Oil (Olive) 0.91 1431 4694.9 2.75 100.000 91.2

Página 16 - 4-20 mA

TFX Communications Using UltraLinkThe current implementa tion of the UltraLink software utility was originally developed for Windows95, Windows 98, an

Página 17 - ISO-Mods

This converter is required regardless of the operating system or the type of port on the computer.The next step up is the infrared connections used on

Página 18

USB (Universal Serial Buss) PortsUSB ports also come in a variety of physical configurations. The two most common are USB Aand USB B. In most computer

Página 19

The device manager window should look something like this.Communicating with UltraLinkOnce the com port properties are known the nextstep is to config

Página 20 - 1. Mounting Location

The figure on the left shows a typical communications setup for a TFXL, HTTF, or PTTF.The TFXL, HTTF, and PTTF all use astandard RS232 com port type.T

Página 21 - Table 2.1

Verifying CommunicationsThere are several possible combinations of indicators that signal communications status. In thelower right hand corner of the

Página 22 - 2. Transducer Spacing

Digital Communications Protocol for TFX Flow MetersHost protocolA digital communications protocol is utilized. Each message is guarded with the standa

Página 23 - Mounting Mode

Special codesThe following special 65 and 66 codes are supported.Code Description00 Echo (for comm debugging)0A Read run time data (signal strength, f

Página 24 - Entering Pipe

Rev. 5/09 -1.10- TFXP PART 1 - TFXP TRANSMITTER CONNECTIONS After unpacking, it is recommended to sav

Página 25

C Source CodeFlow Data Definitionstruct FLOWDATA{short sSignalStrength;double dCurFlowRate;double dNetTotalizer;double dPositiveTotalizer;double dNega

Página 26 - 3. Transducer Mounting

0x4400, 0x84C1, 0x8581, 0x4540, 0x8701, 0x47C0, 0x4680, 0x8641, 0x8201, 0x42C0, 0x4380, 0x8341, 0x4100, 0x81C1, 0x8081, 0x4040,};unsigned short c

Página 27

“STEEL, STAINLESS STEEL, P.V.C. PIPE”STANDARD CLASSESNominal Pipe Size InchesOutside DiameterSCH 5SCH 10(Lt Wall)SCH 20 SCH 30 STD SCH 40ID Wall ID Wa

Página 28 - Positioning

“STEEL, STAINLESS STEEL, P.V.C. PIPE”STANDARD CLASSESNominal Pipe Size InchesOutside DiameterSCH 60 X STG. SCH 80 SCH 100 SCH 120/140 SCH 180ID Wall I

Página 29

Ductile Iron Pipe (Standard Classes)Size(Inches)ClassMortarLiningSize(Inches)ClassMortarLining50 51 52 53 54 55 56 50 51 52 53 54 55 563”O.D. 3.96 3.9

Página 30

Nominal DiameterCOPPER TUBINGCopper & Brass PipeALUMINUMNominal DiameterCOPPER TUBINGCopper & Brass PipeALUMINUMType TypeKLM KLM½”O. D. 0.625

Página 31 - Z-Mount

Cast Iron Pipe (Standard Classes)Size(Inches)ClassSize(Inches)ClassABCDEFGH ABCDEFGH3”O.D. 3.80 3.96 3.96 3.9624”O.D.25.80 25.80 26.32 26.32 26.90 26.

Página 32

NominalPipe(Inches)I.D. INCH1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 91 1.05 2.6989 4.0484 5.3978 6.7473 8.097 9.4462 10.796 12.145 13.490 14.8

Página 33

NominalPipe(Inches)I.D. INCH1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9FPS TO GPM CROSS - REFERENCE (Schedule 40)18 16.88 697.52 1046.3 1395.0 1

Página 34 - Mounting

Limited Warranty and Disclaimer Dynasonics, division of Racine Federated Inc. warrants to the end purchaser, for a period of one year from the dat

Página 35

Rev. 5/09 -1.11- TFXP 1. The connectors located on the side of the TFXP consist of three 1/4-turn BN

Página 36 - 4. RTD INSTALLATION

RETURN OF EQUIPMENT/SALES INFORMATION CONTACTS AND PROCEDURES Customer Service/Application Engineer: If you have a question regarding order status,

Página 37 - Insertion RTD

GENERAL TERMS AND CONDITIONS OF SALES 1. PAYMENT – Terms of payment are effective from the actual date of invoice. If, in the Seller’s opinion,

Página 38

© 2009 Racine Federated Inc. All rights reserved. Printed in the USA TFXP O&M REV 5/09 DYNASONICS is a registered trademark of Racine Fed

Página 39 - Startup

Rev. 5/09 -1.12- TFXP Battery Charging and External Power Sources The 12 volt DC power converter and

Página 40 - Operation

Rev. 5/09 -1.13- TFXP NOTE: The TFXP will automatically enter a low power consumption mode approxima

Página 41 - Configuration

Rev. 5/09 -1.14- TFXP The standard 4-20 mA output may be replaced with one of the following five ISO-

Página 42 - Structure

Rev. 5/09 -1.15- TFXP A 200,000-point Data Logger* is located within the weather-tight pocket on the

Página 43 - BSC MENU -- BASIC MENU

Rev. 5/09 -1.16- TFXP PART 1 - INTRODUCTION NOTES

Página 44

Rev. 5/09 - 2.1 - TFXP The transducers that are utilized by the TFXP contain piezoelectric c

Página 46 - Material

Rev. 5/09 - 2.2 - TFXP The first step in the installation process is the selection of an opt

Página 47

Rev. 5/09 - 2.3 - TFXP Table 2.11 — Piping Configuration and Transducer Positioning 1 The

Página 48

Rev. 5/09 - 2.4 - TFXP TFX transit time flow meters are sold with four different transducer

Página 49 - Heat Capacity

Rev. 5/09 - 2.5 - TFXP Table 2.2 — Transducer Mounting Modes - DTTN / DTTH Transducer Moun

Página 50

Rev. 5/09 - 2.6 - TFXP The TFX system calculates proper transducer spacing by utilizing pipi

Página 51 - Engineering

Rev. 5/09 - 2.7 - TFXP The following information is required before programming the instrume

Página 52

Rev. 5/09 - 2.8 - TFXP After selecting an optimal mounting location (Step 1) and successfull

Página 53

Rev. 5/09 - 2.9 - TFXP The spacing between the transducers is measured between the two spaci

Página 54

Rev. 5/09 - 2.10 - TFXP 2. Place the upstream transducer in position and secure with a mounti

Página 55 - (Optional)

Rev. 5/09 - 2.11 - TFXP 4. If after adjustment of the transducers the signal strength does n

Página 56 - 2. DATALOG OPERATION MENU

Rev. 5/09 -1.1- TFXP BEFORE OPERATING THE TFXP The TFXP flow meter is equipped with a lead-acid Gel

Página 57 - Duration

Rev. 5/09 - 2.12 - TFXP DTTH High Temperature Transducers Mounting of high temperature trans

Página 58

Rev. 5/09 - 2.13 - TFXP 2. On horizontal pipes, mount the transducer in an orientation so th

Página 59 - 3. DATALOG MAINTENANCE

Rev. 5/09 - 2.14 - TFXP 3. Crease the paper at the fold line. Mark the crease. Place a mark

Página 60

Rev. 5/09 - 2.15 - TFXP 5. For DTTN transducers, place a single bead of couplant, approximate

Página 61

Rev. 5/09 - 2.16 - TFXP D010-2102-010 Mounting Track Installation 1. The D010-2102-010 tran

Página 62 - 4. OUTPUT 2 MENU

Rev. 5/09 - 2.17 - TFXP 6. Secure with the thumb screw. Ensure that the screw rests in the

Página 63

Rev. 5/09 - 2.18 - TFXP For typical installations, the length of RTD wire should equal the le

Página 64 - 4-20 mA Span

Rev. 5/09 - 2.19 - TFXP Insertion RTD Installation Insertion RTDs are typically installed th

Página 65 - Calibration

Rev. 5/09 - 2.20 - TFXP Figure 2.14 — Insertion RTD Installation Figure 2.15 — Insertion RTD

Página 66

Rev. 5/09 -3.1- TFXP NOTE: The TFX flow meter system requires a full pipe of liquid before a successf

Página 67 - Rate Pulse

Rev. 5/09 -1.2- TFXP TABLE OF CONTENTS Pages Quick-Start Operating Instructions 1.4 - 1.6 Intro

Página 68 - Programming

Rev. 5/09 -3.2- TFXP After installation of the transducers and connection of appropriate cabling to th

Página 69 - Dual Relay

Rev. 5/09 -3.3- TFXP “Soft Key” menu items will be displayed immediately above the two keys located in

Página 70 - Batch/Totalize

Rev. 5/09 -3.4- TFXP Display Contrast In the RUN mode pressing the SELECT soft key highlights one of t

Página 71

Rev. 5/09 -3.5- TFXP Units Selection 5. Sensor Menu – The Sensor menu is used to select the sensor ty

Página 72

Rev. 5/09 -3.6- TFXP Transducer Mounting Method XDCR MNT -- Transducer Mounting Method (Choice) 1. V 2

Página 73

Rev. 5/09 -3.7- TFXP 16. St Steel 302/303 (SS 303) 17. St Steel 304/316 (SS 316) 18. St Steel 410 (S

Página 74 - SEC MENU -- SECURITY MENU

Rev. 5/09 -3.8- TFXP If a pipe material was chosen from the Pipe Mat list, a nominal value for relativ

Página 75 - SER MENU -- SERVICE MENU

Rev. 5/09 -3.9- TFXP Liner Sound Speed LINER SS -- Speed of Sound in the Liner (Value) 1. ENGLSH

Página 76

Rev. 5/09 -3.10- TFXP FLUID SS -- Speed of Sound in the Fluid (Value) 1. ENGLSH (Feet per Second)

Página 77 - DSP MENU -- DISPLAY MENU

Rev. 5/09 -3.11- TFXP If a fluid was chosen from the Fl Type list, a nominal value for specific gravit

Página 78 - Timeout

Rev. 5/09 -1.3- TFXP TABLE OF CONTENTS Pages Keypad Entry Detail 3.4 - 3.33 BASIC MENU 3.4 -

Página 79 - PART 4 - SOFTWARE UTILITIES

Rev. 5/09 -3.12- TFXP Table 3.2 — Specific Heat Capacity Values for Ethylene Glycol/Water Specific He

Página 80

Rev. 5/09 -3.13- TFXP Transducer Spacing XDCR SPAC -- Transducer Spacing Calculation (Value) 1. ENGLS

Página 81

Rev. 5/09 -3.14- TFXP Engineering Units TOTALIZER Engineering Units RATE INTERVAL 8. Liquid Barrels (

Página 82

Rev. 5/09 -3.15- TFXP Engineering Units TOTAL Exponent Minimum Flow Rate 13. Millions of BTUs (MMBTU)

Página 83

Rev. 5/09 -3.16- TFXP MAX RATE -- Maximum Flow Rate Settings (Value) Rate Unit/Rate Interval A maximu

Página 84

Rev. 5/09 -3.17- TFXP I/O module bay number 1 is reserved exclusively for the ISO Data Logger module.

Página 85

Rev. 5/09 -3.18- TFXP File Number or Location Data Logger Configuration NOTE: The logger will not aut

Página 86

Rev. 5/09 -3.19- TFXP DATALOG INT -- Datalog Interval (Value) ((Sec)) 1 to 30,000 From the Datalog Op

Página 87

Rev. 5/09 -3.20- TFXP Also included with the data logging package is a stand-alone power supply for us

Página 88

Rev. 5/09 -3.21- TFXP Datalog Maintenance permits files to be deleted from the data logger module. Th

Página 89

Rev. 5/09 -1.4- TFXP This manual contains detailed operating instructions for all aspects of the TFX

Página 90

Rev. 5/09 -3.22- TFXP This number will appear in the “Name” column on the computer screen before data

Página 91

Rev. 5/09 -3.23- TFXP NOTES: Data logger must be stopped before downloading data. If data logger is no

Página 92

Rev. 5/09 -3.24- TFXP ISO-MOD: 4-20 mA Module (Optional) The second I/O bay is internal to the TFXP

Página 93

Rev. 5/09 -3.25- TFXP The 4-20 mA output can be configured to source current (internally powered) or s

Página 94

Rev. 5/09 -3.26- TFXP 4-20 mA Span External Power Configuration (Current Sink): If the 4-20 mA output

Página 95

Rev. 5/09 -3.27- TFXP 4-20 mA Calibration Example 1: To span the 4-20 mA output from -100 GPM to +100

Página 96

Rev. 5/09 -3.28- TFXP NOTE: The CAL 4MA and CAL 20MA entries should not be used in an attempt to set

Página 97

Rev. 5/09 -3.29- TFXP 4-20 mA Test ISO-MOD: Rate Pulse Module (Optional) 4-20 TST -- 4-20mA Output T

Página 98

Rev. 5/09 -3.30- TFXP Example 2: To span the 0 to 2.5k Hz output from 0 GPM to +100 GPM, with 1.25k H

Página 99

Rev. 5/09 -3.31- TFXP ISO-MOD: Dual Relay Module (Optional) RELAY -- Dual Relay (Choices and Values)

Página 100 - HEAT FLOW ADDENDUM

Rev. 5/09 -1.5- TFXP 2. TRANSDUCER/POWER CONNECTIONS A. Route the transducer cables from the transdu

Página 101

Rev. 5/09 -3.32- TFXP Flow Rate Relay Batch/Totalize Mode Totalize mode configures the relay(s) to out

Página 102

Rev. 5/09 -3.33- TFXP Signal Strength Alarm Errors Alarm Relay The Sig Str alarm will provide an indi

Página 103 - APPENDIX

Rev. 5/09 -3.34- TFXP ISO-MOD: RS232C Module (Optional) RS232C -- RS232C (Choice) Baud Rate (RS23

Página 104 - DATALOG

Rev. 5/09 -3.35- TFXP ISO-MOD: RS485 Module (Optional) RS485 -- RS485 (Choices and Values) RS485 Mode

Página 105 - DSP MENU

Rev. 5/09 -3.36- TFXP System RESET Totalizer RESET The SEN MENU is utilized to select the type of tran

Página 106 - TFX Error Codes

Rev. 5/09 -3.37- TFXP Substitute Flow Entry Change Password Signal Strength Cutoff CH PSWD? -- Change

Página 107 - 42,000 pulses per min

Rev. 5/09 -3.38- TFXP Setting/Calibrating Zero Flow SET ZERO -- Calibrating Zero Flow (Choice) 1. No

Página 108 - 39,000 pulses per min

Rev. 5/09 -3.39- TFXP Correction Factor Graphics Display Mode the meter. This is not as desirable as t

Página 109 - = 99.1 GPM

Rev. 5/09 -3.40- TFXP Back Light Timeout BACK LIGHT -- Back Light Timeout (Choice) 1. 30 Seconds (

Página 110 - Fluid Properties

Rev. 5/09 -4.1- TFXP PART 4 - SOFTWARE UTILITIES The TFXP flow meter can be used with two software utilities, ULT

Página 111

Rev. 5/09 -1.6- TFXP Startup QUICK-START OPERATING INSTRUCTIONS C. Apply a single 1/2" (12 mm)

Página 112

Rev. 5/09 -4.2- TFXP Initialization Connect the infrared communications adapter to a PC communication port and p

Página 113

Rev. 5/09 -4.3- TFXP The first screen that appears after clicking the Configuration button is the BASIC tab. See

Página 114

Rev. 5/09 -4.4- TFXP Transducer Mount selects the orientation of the transducers on the piping system. See Part

Página 115

Rev. 5/09 -4.5- TFXP Flow Tab Flow Rate Units are selected from the pull-down lists. Select an appropriate rate

Página 116

Rev. 5/09 -4.6- TFXP The Damping value is increased to improve stability of the flow rate readings. Damping valu

Página 117

Rev. 5/09 -4.7- TFXP Substitute Flow is used to provide an indication and output that signifies that an error exi

Página 118 - Host protocol

Rev. 5/09 -4.8- TFXP Time Domain Filter adjusts the number of raw data sets (the wave forms viewed on the ULTRALI

Página 119

Rev. 5/09 -4.9- TFXP Flow Filter MinHysteresis sets a minimum hysteresis window that is invoked at sub 0.25 FPS (

Página 120

Rev. 5/09 -4.10- TFXP Output Tab The entries made in the Output tab establish input and output calibration and r

Página 121

Rev. 5/09 -4.11- TFXP Calibration/Test is used to adjust the factory calibration span of the 4-20 mA output and t

Página 122 - STANDARD CLASSES

Rev. 5/09 -1.7- TFXP PART 1 - INTRODUCTION The TFXP ultrasonic flow meter is designed to measure the

Página 123

Rev. 5/09 -4.12- TFXP Setting Zero and Calibration ULTRALINK™ contains a powerful multi-point calibration routi

Página 124

Rev. 5/09 -4.13- TFXP The final screen (Page 3 of 3) shown in Figure 4.9 on page 4.14 allows multiple actual flow

Página 125 - ALUMINUM

Rev. 5/09 -4.14- TFXP Saving the Configuration Printing a Report Saving Meter Configuration on a PC The complete

Página 126

Rev. 5/09 -4.15- TFXP During the installation of ULTRALINK™, a file called Data Logger was installed and its icon

Página 127

Rev. 5/09 -4.16- TFXP Figure 4.11 — File Uploading Figure 4.12 —

Página 128

Rev. 5/09 -4.17- TFXP The data logger module contains a real-time clock that can be set by clicking the Clock but

Página 129

Rev. 5/09 -4.18- TFXP NOTES PART 4 - SOFTWARE UTILITIES

Página 130 - CONTACTS AND PROCEDURES

Rev. 5/09 -A.1- TFXP The TFX flow meter with the optional RTD (heat flow) Module installed is design

Página 131

Rev. 5/09 -A.2- TFXP Installation Installation 1. Follow the instructions outlined in the standard

Página 132

Rev. 5/09 -A.3- TFXP 5. Route a cable from the electrical junction box back to the TFX flow meter.